What Temperature Should You Set the Thermostat in Winter?

Table of Contents

Most winter thermostat advice starts and ends with one number, which is not much help when the house feels cold at that number or the heat pump reacts badly to a setback. The right setting depends on who is home, when they are home, what kind of system you have, and how the house holds heat. Here is a practical range and a schedule you can adapt.

The Working Answer: 68°F Awake, 60°F to 62°F Asleep

For most occupied homes, 68°F during the day is the standard recommendation, and it is a reasonable starting point rather than a rule. The Department of Energy and many utilities cite 68°F for waking hours and a lower setting overnight or when the house is empty.

For healthy adults, 60°F to 62°F at night is usually acceptable, especially with a warm blanket. Households with infants, older adults, or anyone who is ill should stay closer to 68°F to 70°F. A floor of 55°F applies to any home that will be empty, to protect pipes.

Every degree matters, but not equally. Raising the setpoint by one degree typically adds a few percent to heating energy use, and the exact amount depends on the outdoor temperature, the home's insulation, and the system. The bigger savings usually come from air sealing and insulation, not from shaving one degree.

A Setback Plan That Fits a Workday

If the house is empty from 9 a.m. to 5 p.m., a modest setback is worth it. For a conventional furnace, a drop of 7°F to 10°F for eight hours is the classic recommendation. For a heat pump, use a smaller drop, as explained below.

Time blockSetpointNotes
6:30 a.m. to 9:00 a.m.68°FMorning comfort; recover from the overnight setback before wake-up.
9:00 a.m. to 5:00 p.m.62°F to 64°FEmpty house. Do not drop below 60°F if pets or plants are sensitive.
5:00 p.m. to 10:30 p.m.68°FEvening occupancy. Add a sweater before adding degrees.
10:30 p.m. to 6:30 a.m.60°F to 62°FSleep. Use an extra blanket rather than a warmer setting.
Long trip55°FNever off. Arrange a check-in and a temperature alert.

Adjust the times to your household, not the other way around. A schedule that recovers at 6 a.m. for a 6:30 wake-up is useful; one that starts at 6 a.m. for an 8 a.m. departure wastes energy.

In a two-story house, one thermostat usually serves both floors, and warm air collects at the top of the stairs. A single setback can leave the first floor cold while the second floor overshoots. If the house has zones, set each zone separately. If it does not, keep the stairwell open and use the fan's circulate mode to mix air before judging the setpoint.

Heat Pumps Need Smaller Steps

A heat pump moves heat rather than generating it, and its efficiency drops as the outdoor temperature falls. When a conventional thermostat sees a large setback, it calls for full capacity plus auxiliary resistance heat to recover quickly. That resistance heat can cost several times as much per unit of heat as the compressor.

For most heat pumps, a setback of 2°F to 3°F is a safer choice, with a longer recovery window. Modern variable-speed and cold-climate heat pumps modulate more gracefully and can often handle a larger setback, but the thermostat's auxiliary-heat lockout and balance-point settings still matter. If the system has a smart recovery feature, let it start 30 to 60 minutes before you wake up instead of blasting strips at the last minute.

Do not use emergency heat as a recovery strategy. It locks out the compressor entirely and is meant for a failure, not a cold morning. A heat pump and a furnace behave differently in cold weather, and the thermostat schedule should reflect which one you have.

Humidity, Pets, Babies, and Older Adults

Temperature is only part of comfort. Indoor relative humidity in the 30% to 50% range feels better at a lower thermostat setting, and in winter 30% to 40% is usually enough to avoid window condensation. Too dry causes static, cracked wood, and irritated sinuses; too humid fogs the windows and can feed mold.

Most healthy pets are comfortable at the same temperatures people are, roughly 68°F to 72°F, and should not be left below 60°F for long periods. Short-haired, very young, very old, or arthritic animals may need warmer conditions. Reptiles and tropical fish have specific requirements that a house setback can violate.

Infants and older adults lose heat faster and may not communicate discomfort. Keep rooms used by infants at about 68°F to 72°F and dress them in layers rather than overheating the room. Check on older relatives, especially during cold snaps, and keep their main living space near 68°F to 70°F.

Why 78°F Does Not Heat the Room Faster

Turning the thermostat up does not make a standard furnace or heat pump heat faster. A single-stage system runs at one output until the setpoint is reached, so a higher setting only extends the run time and wastes energy. A two-stage or variable-speed system may ramp up, but it still responds to the difference between the room and the setpoint, not to how impatient you feel.

If a room feels cold at 68°F, the cause is often not the air temperature. Cold window glass, drafts, and uninsulated walls pull heat off your body, which is why a room can measure 68°F and still feel uncomfortable. Air sealing, window coverings, and rugs often do more than a higher setpoint.

Thermostat location matters too. A unit near a sunny window, a supply register, or an exterior door reads the wrong temperature and can leave the rest of the house cold. A remote sensor or a different location can fix a problem that no setpoint will.

Smart Thermostat Settings Worth Using

A smart thermostat earns its price through schedules, remote sensors, and alerts, not through a magic algorithm. Set a schedule that matches the household, use sensors in the rooms you actually occupy, and enable a low-temperature alert for trips. Geofencing can help in an unpredictable household, but it can also heat or cool an empty house if the phone location is unreliable.

Look at the auxiliary-heat and balance-point settings if you have a heat pump. Many installers set the balance point and lockout conservatively, and the defaults are not always right for the house. A smart thermostat saves money only when the schedule and the equipment settings match the building, and learning features need a few weeks of consistent occupancy to be useful.

Be careful with utility demand-response programs. They can reduce bills, but a setback during a cold snap may be noticeable. Read the terms and know how to opt out for a medical need.

Low-Cost Changes That Make 66°F to 68°F Comfortable

Comfort at a lower setpoint comes from the envelope and from personal heat, not from the thermostat alone.

  • Seal obvious drafts around doors, windows, and rim joists.
  • Hang thermal curtains or cellular shades and close them at night.
  • Reverse ceiling fans to low speed so warm air near the ceiling mixes down.
  • Add rugs over cold floors and slippers for the people standing on them.
  • Use a humidifier to keep winter humidity near 35%.
  • Heat only the room you use, with a safe, listed space heater, rather than raising the whole house.
  • Keep interior doors open so return air can circulate.

Do not close supply registers in unused rooms and expect to save money. Pressure imbalances can push conditioned air out through leaks and make the rest of the house less comfortable.

Frequently Asked Questions

Is 68°F too cold for a house in winter?

It is a common recommendation for healthy adults and is comfortable for many households with a sweater and normal humidity. Infants, older adults, and anyone who is ill may need 70°F or more.

What is the best thermostat setting at night?

About 60°F to 62°F for healthy adults. Use a blanket and a programmable recovery that starts before wake-up rather than overheating the bedroom all night.

Should I turn the heat off when I leave for work?

No. Set it back to 62°F to 64°F for the day. Turning it off can let the house cool too far and, in very cold weather, put pipes at risk.

Do heat pumps need a different schedule?

Yes. Use a smaller setback, about 2°F to 3°F, and a longer recovery. Large setbacks can trigger expensive auxiliary resistance heat.

Does lowering the thermostat at night really save money?

It usually does, because the house loses less heat while it is cooler. The savings depend on the length of the setback, the outdoor temperature, and how quickly the system recovers.

What temperature should an empty house be?

55°F is the common minimum for pipe protection. In severe cold or a poorly insulated house, use 60°F and arrange a check-in or monitoring.

See Also